Brick+Work

Zapata-King C2 Corner Lot, 28 Potential Units with Tier 2 TOC

Zapata-King C2 Corner Lot, 28 Potential Units with Tier 2 TOC

APN: 5101-032-030

Print Friendly and PDF

Print Friendly, PDF & Email
C2-1VL-CPIO
Zone/District
28
Max Unit
6,525 sq. ft.
Lot Size
Tier 2
TOC
1
Lots
Existing Conditions
Floor Area 2,926 sq. ft. (combined)
Units 4 (combined)
Year Constructed 1920-1935
Assessed Improvement Value $170,643
Assessed Land Value $168,894
Development Potential (By-Right)
Maximum FAR 1.5:1
Maximum Height
Feet

45 ft.

Minimum ground floor height of 14 ft.

Stories

3

Buildings used entirely for residential uses (and ground floor commercial in RAS zones) are only limited in height, not stories.

Minimum Setbacks
Front

6 ft.

For Mixed-Use Projects, no setback requirements shall apply to any portion of a street facing building frontage used for residential uses.

Side

0 ft. for commercial uses; 5 ft. for residential uses

For Mixed-Use Projects, no setback requirements shall apply to any portion of a street facing building frontage used for residential uses.; for residential use, add 1 foot of side setback for each story over 2, not to exceed 16 ft.

Back

0 ft. for commercial uses; 15 ft. for residential uses

for residential uses, add 1 foot of back setback for each story over 3, not to exceed 20 ft.

Max Buildable Area, Footprint 6,525 sq. ft.
Max Buildable Area, Envelope 9,788 sq. ft.
Max Dwelling Units 16
Affordable Units Required at least 15% of all new and rehabilitated dwelling units developed within the Project Area by public or private entities shall be available at affordable housing cost to persons and families of low- or moderate-income; and of such 15%, not less than 40% shall be available at affordable housing cost to very low-income households
Parking Required 1 space per unit with less than 3 habitable rooms 1.5 spaces per unit with 3 habitable rooms 2 spaces per unit with more than 3 habitable rooms 1 space per guest room (first 30)
Required Bicycle Parking
Long Term 1 space per unit for units 0-25; 1 spaces per 1.5 units for units 26-100; 1 spaces per 2 units for units 101-200; 1 spaces per 4 units for units 201+
Short Term 1 space per 10 units for units 0-25; 1 spaces per 15 unit for units 26-100; 1 spaces per 20 units for units 101-200; 1 spaces per 40 unit for units 201+
Transitional Height Limitations Where a parcel is either abutting or across an alley from a property in the RD 1.5 or more restrictive zone, the building height shall be stepped-back within a 45 degree angle as measured 15 feet above grade at the property line of the lot in the more restrictive zone
Required Open Space 100 sq ft per unit with less than 3 habitable rooms 125 sq ft per unit with 3 habitable rooms 175 sq ft per unit with more than 3 habitable rooms
Other Development Notes
Development Potential (with TOC or DB)
Maximum FAR 3.25:1
Maximum Height
Feet

56 ft.

Minimum ground floor height of 14 ft.; Projects located in a zone where the maximum height is 45 ft. or less, or located within a Specific Plan that limits height, height increases over 11 ft. must be stepped-back at least 15 ft. from the exterior face of the ground floor building located at any street frontage.

Stories

4

Buildings used entirely for residential uses (and ground floor commercial in RAS zones) are only limited in height, not stories.

Minimum Setbacks
Front

6 ft.

For Mixed-Use Projects, no setback requirements shall apply to any portion of a street facing building frontage used for residential uses.

Side

0 ft. for commercial uses; 5 ft. for residential uses

For Mixed-Use Projects, no setback requirements shall apply to any portion of a street facing building frontage used for residential uses.

Back

0 ft. for commercial uses; 15 ft. for residential uses

add 1 foot of back setback for each story over 3, not to exceed 20 ft.

Max Buildable Area, Footprint 6,525 sq. ft.
Max Buildable Area, Envelope 21,206 sq. ft.
Max Dwelling Units 28
Affordable Units Required at least 9% for Extremely Low Income, or 12% for Very Low Income, or 21% for Low Income
Parking Required Shall not exceed 0.5 space per unit
Required Bicycle Parking
Long Term 1 space per unit for units 0-25; 1 spaces per 1.5 units for units 26-100; 1 spaces per 2 units for units 101-200; 1 spaces per 4 units for units 201+
Short Term 1 space per 10 units for units 0-25; 1 spaces per 15 unit for units 26-100; 1 spaces per 20 units for units 101-200; 1 spaces per 40 unit for units 201+
Transitional Height Limitations Where a parcel is either abutting or across an alley from a property in the RD 1.5 or more restrictive zone, the building height shall be stepped-back within a 45 degree angle as measured 15 feet above grade at the property line of the lot in the more restrictive zone. For all CPIO Affordable Housing Projects, Density Bonus Projects and TOC Projects, that are either abutting or across an alley from a property in the RD 1.5 or more restrictive zone, the required height transition applies only to the first 25 feet of depth as measured from the property line of the lot in the more restrictive zone.
Required Open Space Up to 20% decrease in required open space
Other Development Notes
Jurisdictional
Legal Description Lot FR 30, Block F, The Mc Carthy Company's Main Street Moneta Avenue and Figeroa St. TR NO. 2
Land Use Neighborhood Commercial
Area Planning Commission South Valley
Community Plan Area Southeast Los Angeles
Neighborhood Council Zapata-King
Council District 9
Councilmember Curren D. Price, Jr.
Red Flags
Property is subject to the requirements of the South Los Angeles Alcohol Sales Specific Plan, which could limit the development potential of the site
Development Plans on this property will be subject to review by the Council District 9 Redevelopment Project. This could also limit the utilization of TOC incentives.
Property is subject to the requirements of the Southeast Los Angeles Community Plan Implementation Overlay, which could limit the development potential of the site
BRICK+WORK Analyzer
Calculator
Please Enter Land Cost.
Please Enter Average Rents in Area.
Ask Administrator to enter the required values for the calculation of Financial Analyser.
Particulars By-Right TOC or DB
Total Buildable
Net Buildable
Average Construction Cost
Total Construction Budget
Total Soft Costs
Total Development Budget
Gross Annual Rents
Expenses (25%)
NOI
Valuation
Equity After Completion
Equity Multiple
IRR

Property Report Disclaimer

All data are obtained from government sources. No attempt has been made to verify the data’s accuracy.

This report is for informational purposes only. Do not rely on this report to support real estate or investment decisions. The only authoritative source for the information in this report is the government agencies from which the data was obtained.

By publishing this property, you represent and warrant that you have obtained the authorization from the property owner to market this property AND to take actions on behalf of the property owner.