Brick+Work

Echo Park Combined Vacant Lots, 86 Potential Units

Los Angeles

Echo Park Combined Vacant Lots, 86 Potential Units

APN: 5405021021, 5405021024, 5405021026

$

$
C2-1VL
Zone/District
86
Max Unit
22,557 sq. ft.
Lot Size
Tier 1
TOC
3
Lots
Existing Conditions
Floor Area 0 sq. ft.
Units 0
Year Constructed N/A
Assessed Improvement Value $0 (combined)
Assessed Land Value $1,609,044 (combined)
Development Potential (By-Right)
Maximum FAR 1.5:1
Maximum Height
Feet

45 ft.

Stories

3

Buildings used entirely for residential uses (and ground floor commercial in RAS zones) are only limited in height, not stories.

Minimum Setbacks
Front

0 ft.

Side

5 ft.

setbacks required only for residential stories; add 1 foot of side setback for each story over 2, not to exceed 16 ft.; no side setback required for commercial only uses; no side setbacks required for mixed use project abutting street or alley

Back

15 ft.

setbacks required only for residential stories; add 1 foot of back setback for each story over 3, not to exceed 20 ft.; no rear setback required for commercial only uses; no rear setbacks required for mixed use project abutting street or alley

Max Buildable Area, Footprint 19,170 sq. ft.
Max Buildable Area, Envelope 33,836 sq. ft.
Max Dwelling Units 56
Affordable Units Required None
Parking Required 1 space per unit with less than 3 habitable rooms 1.5 spaces per unit with 3 habitable rooms 2 spaces per unit with more than 3 habitable rooms 1 space per guest room (first 30)
Required Bicycle Parking
Long Term 1 space per unit for units 0-25; 1 spaces per 1.5 units for units 26-100; 1 spaces per 2 units for units 101-200; 1 spaces per 4 units for units 201+
Short Term 1 space per 10 units for units 0-25; 1 spaces per 15 unit for units 26-100; 1 spaces per 20 units for units 101-200; 1 spaces per 40 unit for units 201+
Transitional Height Limitations Portions of Buildings in C or M zones with certain distances of RW1 or more restrictive zones shall not exceed the following limits: Distance (ft.) Height (ft.) 0-49 25 50-99 33 100-199 61
Required Open Space 100 sq ft per unit with less than 3 habitable rooms 125 sq ft per unit with 3 habitable rooms 175 sq ft per unit with more than 3 habitable rooms
Other Development Notes
Development Potential (with TOC or DB)
Maximum FAR 2.75:1
Maximum Height
Feet

56 ft.

Stories

4

Buildings used entirely for residential uses (and ground floor commercial in RAS zones) are only limited in height, not stories.

Minimum Setbacks
Front

0 ft.

Side

5 ft.

side setback required for portions of buildings erected for residential uses, no setbacks required for ground floor commercial; no setbacks required for mixed use project abutting street or alley

Back

15 ft.

no setbacks required for mixed use project abutting street or alley or commercial only uses

Max Buildable Area, Footprint 19,170 sq. ft.
Max Buildable Area, Envelope 62,032 sq. ft.
Max Dwelling Units 86
Affordable Units Required at least 8% for Extremely Low Income, or 11% for Very Low Income, or 20% for Low Income
Parking Required Shall not exceed .5 space per bedroom
Required Bicycle Parking
Long Term 1 space per unit for units 0-25; 1 spaces per 1.5 units for units 26-100; 1 spaces per 2 units for units 101-200; 1 spaces per 4 units for units 201+
Short Term 1 space per 10 units for units 0-25; 1 spaces per 15 unit for units 26-100; 1 spaces per 20 units for units 101-200; 1 spaces per 40 unit for units 201+
Transitional Height Limitations The building height shall be stepped back The building height limit shall be stepped-back at a 45-degree angle as measured from a horizontal plane originating 15 feet above grade at the property line of the adjoining lot.
Required Open Space Up to 20% decrease in required open spaceea
Other Development Notes
Jurisdictional
Legal Description Lots 55, 57, & 59, Block 28, Angeleno Heights Tract
Land Use General Commercial
Area Planning Commission East Los Angeles
Community Plan Area Silver Lake-Echo Park-Elysian Valley
Neighborhood Council Echo Park
Council District 1
Councilmember Gilbert Cedillo
Red Flags
Property is subject to the City of Los Angeles Baseline Hillside Ordinance, which could limit the development potential of the site
BRICK+WORK Analyzer
Calculator
Please Enter Land Cost.
Please Enter Average Rents in Area.
Ask Administrator to enter the required values for the calculation of Financial Analyser.
Particulars By-Right TOC or DB
Total Buildable
Net Buildable
Average Construction Cost
Total Construction Budget
Total Soft Costs
Total Development Budget
Gross Annual Rents
Expenses (25%)
NOI
Valuation
Equity After Completion
Equity Multiple
IRR

Property Report Disclaimer

All data are obtained from government sources. No attempt has been made to verify the data’s accuracy.

This report is for informational purposes only. Do not rely on this report to support real estate or investment decisions. The only authoritative source for the information in this report is the government agencies from which the data was obtained.

By publishing this property, you represent and warrant that you have obtained the authorization from the property owner to market this property AND to take actions on behalf of the property owner.